FS-IR1909A 24V Waterproofing Optical Water Controller Liquid Tank Level Sensor
Application
Medical devices or equipment
Electrical equipment
Electrical appliances and equipment's etc. requiring liquid-level control
Product features
No mechanical moving components and with high reliability
Strong corrosion resistance
High liquid level control precision and can be installed from any direction
The sensor itself satisfies RoHS requirements
Waterproof standard IP68
Electrical Specification(Ta=25°C)
Outline Drawing



Company Information






Application
Medical devices or equipment
Electrical equipment
Electrical appliances and equipment's etc. requiring liquid-level control
Product features
No mechanical moving components and with high reliability
Strong corrosion resistance
High liquid level control precision and can be installed from any direction
The sensor itself satisfies RoHS requirements
Waterproof standard IP68
Electrical Specification(Ta=25°C)
parameter | symbol | condition | min | typ | max | units | |
direct-current charecteristic | Working Voltage | VDD | 5 | 24 | 25 | V | |
current | IDD | VDD = 24V in water | - | <15 | - | mA | |
VDD = 24V in air | - | <15 | - | mA | |||
power consumption | PD | VDD = 24V in water | - | <360 | - | mW | |
VDD = 24V in air | - | <360 | - | mW | |||
output characteristic | output voltage in water | VO1 | VDD = 24V Ta = 25ºC | - | <0.30 | - | V |
output voltage in air | VO2 | VDD = 24V Ta = 25ºC | - | >20 | - | V | |
output current | IOL | VDD = 24V Ta = 25ºC | - | <500 | - | mA | |
output current | IOH | VDD = 24V Ta = 25ºC | - | <2 | - | mA | |
response time | VDD = 24V Ta = 25ºC | - | <1 | - | S | ||
limit value | Operating Temperature | Topr | VDD = 24V | -20 | 85 | ºC | |
Storage Temperature | Tstg | - | -40 | 95 | ºC | ||
Working Time | Wt | VDD = 24V Totg = 25ºC | - | 50000 | - | h | |
pressure range | - | -10 | 5 | 10 | bar |